Test 2020-09-28-42-2 (CTM 670-December 2013) Summary

Project Information
Project IdentifiersProject ID: 210673
DEA: 042640F4
EFIS: 0400020132
COOP: 042308A3
DIST-CO-RTE-PM04-SON-101-4.0/7.1
Work DescriptionDESIGN THE NORTHERLY SEGMENT OF THE MARIN-SONOMA NARROWS PROJECT AND INCLUDES SOUND WALLS, BRIDGES, MEDIAN WIDENING AND RAMP WIDENING.
Location DescriptionJUST NORTH OF THE U.S. 101 AND STATE ROUTE 116 CONNECTION TO 0.3 MILE NORTH OF THE CORONA ROAD OVERCROSSING IN THE CITY OF PETALUMA.
Sample Information
Sample Taken Date9/28/2020 Sample Unique Key42
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/6/2020
Sample typeQuality Assurance A brief description of the sampleLenton Couplers
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byHarry Last name of sampler or witnessed bySuryantoro
Title of sampler Laboratory sample identification
The fabricator/manufacturer/facility nameNucor Erico Transportation Laboratory (TL) NumberC866414
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerErico Lenton Intermediate Assembler or Fabricator
Rebar Size#10 Coupler ModelErico Lenton A2
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)LA888 Rebar Heat Number(s)3500005241
Rebar Size 2
Test Details
DIME Sample ID: 2020-09-28-42
DIME Test ID: 2020-09-28-42-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2020-10-07
Test Results

Number of Samples Tested: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 10/07/2020
UTM:400kip
Temperature:72.00 f
Halo ID:
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
12No. 10/32mm101.2711963594200Service Splicefsaylor

General comments (publicly viewable) (Max 250 characters): Service Splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 10/07/2020