Test 2020-09-28-36-1 (AASHTO T27-14) Summary

Project Information
Project IdentifiersProject ID: 7613
DEA: 071218W4
EFIS: 0700021119
DIST-CO-RTE-PM07-LA-5-29.4/31.6
Work DescriptionREALIGN ROUTE 5 AND RAILROAD TRACKS AND RECONFIGURE ON- AND OFF-RAMPS.
Location DescriptionLOS ANGELES COUNTY IN BURBANK FROM WEST MAGNOLIA BOULEVARD OVERCROSSING TO 0.3 MILE NORTH OF BUENA VISTA STREET/WINONA AVENUE UNDERCROSSING
Sample Information
Sample Taken Date9/28/2020 Sample Unique Key36
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/30/2020
Sample typeVerification A brief description of the samplePSUE 1/2" RHMA-G-SP 0.5% LAS
The quantity of what the sample constitutes6 Bags Of Aggregate From where was the sample collectedManufacturer
First name of sampler or witnessed byMichael Last name of sampler or witnessed byBrook
Title of sampler Laboratory sample identification0563G-20
The fabricator/manufacturer/facility nameVulcan Materials Sun Valley 3 Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-19-0035
The fabricator's/manufacturer's product name for the sample1/2 RHMA-G-SP The fabricator/manufacturer designation for the sample
The plant number326120 SVA3 VLO A detailed description of where the material sample was collectedBelt Cut at Vulcan Sun Valley 3
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number JMF Verification ID
Test Details
DIME Sample ID: 2020-09-28-36
DIME Test ID: 2020-09-28-36-1
Testing Lab: CT - Southern Regional Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2020-10-12
Test Results

What type of gradation is being tested?: Combined Gradation
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Input Type: Calculated
Tester's full name: Michael Magana/Sebastian Ferrer
Date of test: 10/06/2020
Cumulative percent passing the 2 in. sieve:100 %
Cumulative percent passing the 1 1/2 in. sieve:100 %
Cumulative percent passing the 1 in. sieve:100 %
Cumulative percent passing the 3/4 in. sieve:100 %
Cumulative percent passing the 1/2 in. sieve:94 %
Cumulative percent passing the 3/8 in. sieve:79 %
Cumulative percent passing the #4 sieve:36 %
Cumulative percent passing the #8 sieve:21 %
Cumulative percent passing the #16 sieve:16 %
Cumulative percent passing the #30 sieve:11 %
Cumulative percent passing the #50 sieve:7 %
Cumulative percent passing the #100 sieve:4 %
Cumulative percent passing the #200 sieve:2.5 %
General comments (publicly viewable) (Max 250 characters): Combined Virgin Aggregate Gradation

Test was verified on 10/12/2020