Summary for Test 2020-09-17-19-7
Test performed: AASHTO T84-14Project Information
Project Identifiers | Project ID: 214629 DEA: 051H9304 EFIS: 0517000017 |
---|---|
DIST-CO-RTE-PM | 05-SLO-46-R17.2/R17.6 |
Award Date | 04/07/2020 |
Closeout Date | 10/20/2022 |
Work Description | CONSTRUCT ROUNDABOUT. |
Location Description | SAN LUIS OBISPO COUNTY NEAR TEMPLETON FROM 0.2 MILE WEST TO 0.2 MILE EAST OF VINEYARD DRIVE |
QA Service Level | 1 (Verified on 02/20/2020) |
Sample Information
Sample Taken Date | 09/17/2020 | Sample Unique Key | 19 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/25/2020 |
Sample type | Verification | A brief description of the sample | Bags of Aggregates |
The quantity of what the sample constitutes | One JMF Verification | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Larry | Last name of sampler or witnessed by | Scott |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | CalPortland Paso Robles | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-40-0013 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | At the Plant | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2020-09-17-19
DIME Test ID: 2020-09-17-19-7
Testing Lab: CT D05 - San Luis Obispo District Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2020-10-01
Test Results
Input Type: Measured
Tester's full name: Daniel Gingras
Date of test: 09/29/2020
Mass of saturated surface dry sample (before pycnometer) (S): 500 grams
Mass of the pycnometer with water and aggregate (C): 954.7 grams
Mass of the pycnometer with water (B): 649.7 grams
Mass of the oven dried sample (before pycnometer) (A): 491.8 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500 grams
Mass of the oven dry aggregate (for absorption) (A): 491.8 grams
Test Sample Preparation: 6% Moisture
Bulk specific gravity: 2.522
Bulk specific gravity (SSD Basis): 2.564
Apparent specific gravity: 2.633
Absorption: 1.7 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/1/2020 ✔