Test 2020-09-25-2-4 (ASTM A884-13) Summary

Project Information
Project IdentifiersProject ID: 214629
DEA: 051H9304
EFIS: 0517000017
DIST-CO-RTE-PM05-SLO-46-R17.2/R17.6
Work DescriptionCONSTRUCT ROUNDABOUT.
Location DescriptionSAN LUIS OBISPO COUNTY NEAR TEMPLETON FROM 0.2 MILE WEST TO 0.2 MILE EAST OF VINEYARD DRIVE
Sample Information
Sample Taken Date9/25/2020 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing9/29/2020
Sample typeAcceptance A brief description of the sample#8 ASTM A615 Grade 75 Soil Nail
The quantity of what the sample constitutes2 From where was the sample collectedFabricator
First name of sampler or witnessed byArthur Last name of sampler or witnessed byPeterson
Title of samplerQA Inspector Laboratory sample identification
The fabricator/manufacturer/facility nameWilliams Form Engineering-SD Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL110-192-20 Structure unique identifier
Structure name
Material Information
Material TypeSMTL TM5 - Threaded Bar Production or Authorization TestingAuthorization Testing
Threaded Bar SpecificationASTM A615 Threaded Bar Grade75
Threaded Bar TypePlain Rebar Size#8
Nut Specification for Threaded Barn/a System ManufacturerWilliams Form Engineering
Epoxy Coating ColorPurple Threaded Bar ApplicationSoil Nail
Coating StandardsASTM A934 epoxy Bar Heat Number(s)100104509
Nut Heat Number(s) Bar Lot Number10010450920
Nut Lot Number Coupler Heat Number(s)
Coupler Grade
Test Details
DIME Sample ID: 2020-09-25-2
DIME Test ID: 2020-09-25-2-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A884-13: Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement (Holiday)
Test Release Date: 2020-10-01
Test Results

Input Type: Measured
Tester's full name: Steven Paine
Date of test: 09/30/2020
Total Number of Holiday: 0
Total Length: 8
Holidays Per Linear Foot of Bar:0
Holiday Test Pass/Fail:Pass
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/01/2020