Test 2020-09-28-18-1 (CTM 670-December 2013) Summary

Project Information
Project IdentifiersProject ID: 213411
DEA: 030H10U4
EFIS: 0317000246
DIST-CO-RTE-PM03-SAC-5-9.7/24.9
Work DescriptionNot set
Location DescriptionConstruction on state highway in Sacramento County in and near Sacramento from 1.1 miles south of Elk Grove Boulevard to American River Viaduct
Sample Information
Sample Taken Date9/28/2020 Sample Unique Key18
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing9/28/2020
Sample typeAcceptance A brief description of the sample#11 Grip-Twist Coupler
The quantity of what the sample constitutes150 Couplers From where was the sample collectedJob Site
First name of sampler or witnessed bySaid Last name of sampler or witnessed byAnam
Title of sampler Laboratory sample identification
The fabricator/manufacturer/facility nameBarSplice Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCamblin Steel
Coupler ManufacturerBarSplice Products Inc Intermediate Assembler or Fabricator
Rebar Size#11 Coupler ModelBarsplice Taper Grip-Twist
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)A201716, A201361 Lot 2 Rebar Heat Number(s)3095554
Rebar Size 2
Test Details
DIME Sample ID: 2020-09-28-18
DIME Test ID: 2020-09-28-18-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2020-10-05
Test Results

Number of Samples Tested: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 09/30/2020
UTM:2000kip
Temperature:72.00 f
Halo ID:Large
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
11No. 11/36mm2-0.00161.5615032296360Ok Neckingbewing

General comments (publicly viewable) (Max 250 characters): Ok Necking
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 10/05/2020