Test 2020-09-23-13-1 (ASTM F606-14a) Summary

Project Information
Project IdentifiersProject ID: 214228
DEA: 120N4904
EFIS: 1214000050
DIST-CO-RTE-PM12-ORA-91-R12.5/R13.9
Work DescriptionVEHICLE ENFORCEMENT FACILITY IMPROVEMENT AT PERALTA WEIGH STATION.
Location DescriptionORANGE COUNTY IN ANAHEIM FROM 1.0 MILE EAST OF ROUTE 91/90 SEPARATION TO 0.5 MILE WEST OF WEIR CANYON ROAD UNDERCROSSING
Sample Information
Sample Taken Date9/23/2020 Sample Unique Key13
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing9/28/2020
Sample typeQuality Assurance A brief description of the sample5/8" HHN HDG
The quantity of what the sample constitutes20 From where was the sample collectedDistributor
First name of sampler or witnessed bySteve Last name of sampler or witnessed byHall
Title of samplerCT METS QA INSPECTOR Laboratory sample identification
The fabricator/manufacturer/facility nameBristol Machine Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL134-218-20 Structure unique identifier
Structure name
Material Information
Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)6215169002 Nut Mfg. Lot Number(s)32395-6215169002
Washer Mfg. Lot Number(s)N/A Bolt SpecificationN/A
Bolt Length(s)N/A Nut SpecificationASTM A563 Gr. DH
Washer SpecificationN/A FinishHDG
Diameter/Size5/8" Bolt Mfg. Lot NumberN/A
Rocap Test Requirement(s) Lubricant Requirements(s)
Test Details
DIME Sample ID: 2020-09-23-13
DIME Test ID: 2020-09-23-13-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2020-09-30
Test Results

Number of Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 09/29/2020
UTM:450kip
Temperature:72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11A32395-621516900236158Nut Proof Loadspaine

General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 09/30/2020