Summary for Test 2020-07-15-44-2

Test performed: AASHTO T51-13

Project Information

Project IdentifiersProject ID: 210618
DEA: 06342534
EFIS: 0600000382
COOP: 061616A2
DIST-CO-RTE-PM06-FRE-180-R74.1/R78.6
Award Date04/05/2017
Closeout Date07/06/2021
Work DescriptionCONSTRUCT SEGMENT 3 OF KINGS CANYON EXPRESSWAY
Location DescriptionFRESNO COUNTY ABOUT 8.4 MILES EAST OF FRESNO FROM 0.7 MILE WEST OF SMITH AVENUE TO 0.7 MILE EAST OF FRANKWOOD AVENUE
QA Service Level1 (Verified on 07/10/2017)

Sample Information

Sample Taken Date07/15/2020 Sample Unique Key44
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/17/2020
Sample typeAcceptance A brief description of the sampleTEST Asphalt Binder
The quantity of what the sample constitutes1 can, #1 TEST (040158) From where was the sample collectedSource
First name of sampler or witnessed byUnknown Last name of sampler or witnessed byUnknown
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameUnknown Transportation Laboratory (TL) Number040158
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 70-10
ModifiedNo Lot number1
Sublot number6 Tank numberNot set
Time of sampleNot set HMA SupplierNot set
Certified Asphalt SupplierNot set MultigradeNot set
Multigrade TypeNot set Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2020-07-15-44
DIME Test ID: 2020-07-15-44-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T51-13: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Test Release Date: 2020-09-30

Test Results


Is a normal test obtainable?: Yes
Number of replicates tested: One
Input Type: Measured
Tester's full name: Juan Gomez
Date of test: 09/23/2020
Ductility of test #1 (D1): 75 cm
Ductility of sample: 75 cm
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/30/2020