Summary for Test 2020-09-02-13-5

Test performed: AASHTO T315-16

Project Information

Project IdentifiersProject ID: 214875
DEA: 033H72U4
EFIS: 0320000087
DIST-CO-RTE-PM03-BUT-70-5.6/9.1
Award Date06/16/2020
Closeout Date08/10/2023
Work DescriptionROADWAY EXCAVATION, PLACE HMA & RHMA, & CONSTRUCT DRAINAGE SYSTEMS.
Location DescriptionBUTTE COUNTY NEAR OROVILLE FROM 0.2 MILE NORTH OF COX LANE TO 0.1 MILE NORTH OF PALERMO ROAD
QA Service Level1 (Verified on 04/15/2020)

Sample Information

Sample Taken Date09/02/2020 Sample Unique Key13
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/10/2020
Sample typeAcceptance A brief description of the sampleAB PG 64-16 #1 test, #2 (766377), #3(766381) No Test
The quantity of what the sample constitutes concrete cylinders From where was the sample collectedSource
First name of sampler or witnessed byE Last name of sampler or witnessed byChavez
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameWestern Refining Elk Grove Transportation Laboratory (TL) Number766375
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
ModifiedNo Lot number
Sublot number Tank numberNot set
Time of sampleNot set HMA SupplierNot set
Certified Asphalt SupplierNot set MultigradeNot set
Multigrade TypeNot set Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2020-09-02-13
DIME Test ID: 2020-09-02-13-5
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2020-09-25

Test Results


Phase: PAV residue
Input Type: Calculated
Tester's full name: Doug Ruff
Date of test: 09/22/2020
Test Plate Diameter: 8 mm
Phase Angle (δ) (for the 10 cycles): 45.8 degree
(G*) x sin(δ)=: 4041 kPa
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/25/2020