Test 2020-08-14-31-5 (AASHTO T283-14) Summary

Project Information
Project IdentifiersProject ID: 214658
DEA: 051K7104
EFIS: 0518000232
DIST-CO-RTE-PM05-SLO-46,101-var
Work DescriptionPLACE METHACRYLATE DECK SEAL, POLYESTER CONCRETE OVERLAY, JOINT SEALS
Location DescriptionSAN LUIS OBISPO COUNTY IN AND NEAR PASO ROBLES AT VARIOUS LOCATIONS
Sample Information
Sample Taken Date8/14/2020 Sample Unique Key31
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing9/9/2020
Sample typeVerification A brief description of the sampleBoxes of HMA-A
The quantity of what the sample constitutesOne JMF Verification From where was the sample collectedManufacturer
First name of sampler or witnessed byMike Last name of sampler or witnessed bySavage
Title of sampler Laboratory sample identification
The fabricator/manufacturer/facility nameSPM Templeton Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number JMF Verification ID JMF3513-2020-204
Test Details
DIME Sample ID: 2020-08-14-31
DIME Test ID: 2020-08-14-31-5
Testing Lab: CT D05 - Field Laboratory
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Test Release Date: 2020-09-25
Test Results

Input Type: Calculated
Tester's full name: QC
Date of test: 08/26/2020
Specimen Treatment: Treated
Average Dry Tensile Strength: 281 psi
Average Wet Tensile Strength: 225 psi
Tensile Strength Ratio:80.1
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 09/25/2020