Summary for Test 2020-07-07-19-5
Test performed: AASHTO T315-16Project Information
Project Identifiers | Project ID: 212535 DEA: 031A9204 EFIS: 0300020608 |
---|---|
DIST-CO-RTE-PM | 03-SUT-20-5-11.3 |
Award Date | 06/11/2019 |
Closeout Date | 12/01/2021 |
Work Description | SUTTER BYPASS WIDENING AND REHAB |
Location Description | NEAR YUBA CITY FROM SUTTER BYPASS TO 0.1 MILE WEST OF LYTLE ROAD. |
QA Service Level | 1 (Verified on 07/23/2018) |
Sample Information
Sample Taken Date | 07/07/2020 | Sample Unique Key | 19 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/16/2020 |
Sample type | Acceptance | A brief description of the sample | TEST Asphalt Binder |
The quantity of what the sample constitutes | 4 cans each, #1 TEST (723288), (#2 723289, #3 723290, #4 723292) | From where was the sample collected | Source |
First name of sampler or witnessed by | M | Last name of sampler or witnessed by | Chittonden |
Title of sampler | TET | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Valero | Transportation Laboratory (TL) Number | 723288 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 64-16 |
---|---|---|---|
Modified | No | Lot number | 1 |
Sublot number | 5 | Tank number | Not set |
Time of sample | Not set | HMA Supplier | Not set |
Certified Asphalt Supplier | Not set | Multigrade | Not set |
Multigrade Type | Not set | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2020-07-07-19
DIME Test ID: 2020-07-07-19-5
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2020-09-23
Test Results
Phase: Original binder
Input Type: Measured
Tester's full name: Eva Torres
Date of test: 08/10/2020
Test Plate Diameter: 25 mm
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.00 %
Stress Amplitude: 0.245 kPa
Phase Angle (δ) (for the 10 cycles): 84.9 degree
Complex Modulus (G*) (for the 10 measurements): 2.040 kPa
Test Temperature (Specimen 1): 64.0 C
Dynamic Shear, G*/sin(δ): 2.05 kPa
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/23/2020 ✔