Summary for Test 2020-09-17-11-4

Test performed: AASHTO T84-14

Project Information

Project IdentifiersProject ID: 214774
DEA: 081F1324
EFIS: 0815000212
DIST-CO-RTE-PM08-SBD-95-64.5/80.5
Award Date05/04/2020
Closeout Date01/18/2022
Work DescriptionPLACE RHMA-G, COLD PLANE AC AND REPLACE AC SURFACING.
Location DescriptionSAN BERNARDINO COUNTY ON ROUTE 95 FROM 0.5 MILE NORTH OF GOFFS ROAD TO NEVADA STATE LINE.
QA Service Level1 (Verified on 08/25/2020)

Sample Information

Sample Taken Date09/17/2020 Sample Unique Key11
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/18/2020
Sample typeVerification A brief description of the samplePSUE 1/2" RMHA-G-SP 0.25% Evo
The quantity of what the sample constitutes2 Bags Of Coldfeed Aggregate From where was the sample collectedManufacturer
First name of sampler or witnessed byVulcan Bullhead City Arizona Last name of sampler or witnessed byQC
Title of sampler Telephone number of sampler
Laboratory sample identification0536-20 Linked DIME Sample ID
The fabricator/manufacturer/facility nameCemex Bullhead City AZ SJR Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)CM2056
The fabricator's/manufacturer's product name for the sample1/2 RHMA-G-SP The fabricator/manufacturer designation for the sample
The plant number387111B A detailed description of where the material sample was collectedBelt Cut at Vulcan Bullead City Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-09-17-11
DIME Test ID: 2020-09-17-11-4
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2020-09-23

Test Results


Input Type: Measured
Tester's full name: Danilo Ferrer
Date of test: 09/22/2020
Mass of saturated surface dry sample (before pycnometer) (S): 500 grams
Mass of the pycnometer with water and aggregate (C): 958.1 grams
Mass of the pycnometer with water (B): 653.2 grams
Mass of the oven dried sample (before pycnometer) (A): 486.3 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500 grams
Mass of the oven dry aggregate (for absorption) (A): 486.3 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity: 2.493
Bulk specific gravity (SSD Basis): 2.563
Apparent specific gravity: 2.681
Absorption: 2.8 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/23/2020