Summary for Test 2014-12-11-1-1

Test performed: CTM 643-June 2007

Project Information

Project IdentifiersProject ID: 210199
DEA: 07286301
EFIS: 0713000216
COOP: 074932
DIST-CO-RTE-PM07-LA--66/70
Award DateNot set
Closeout DateNot set
Work DescriptionWiden Route 138 to 4 lanes with a median turn lane and standard width shoulder.
Location DescriptionIN LOS ANGELES COUNTY IN PALMDALE FROM 0.4 MILE WEST OF 190TH STREET EAST TO ROUTE 18 JUNCTION
QA Service Level2 (Verified on 02/02/2015)

Sample Information

Sample Taken Date12/11/2014 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/11/2014
Sample typePreliminary A brief description of the sampleSoil
The quantity of what the sample constitutes1 Bag From where was the sample collectedSource
First name of sampler or witnessed byKristopher Last name of sampler or witnessed byBarker
Title of samplerEngineering Geologist Telephone number of samplerUnknown
Laboratory sample identification4333B Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameA 14 001 Bulk Transportation Laboratory (TL) NumberC707710
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sampleUnknown
The fabricator/manufacturer designation for the sampleUnknown A detailed description of where the material sample was collectedA 14 001 Bulk
Where the material sample would have been placed if not sampledUnknown

Test Details

DIME Sample ID: 2014-12-11-1
DIME Test ID: 2014-12-11-1-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 643-June 2007: Method for Determining Field and Laboratory Resistivity and pH Measurements for Soil and Water
Test Release Date: 2015-02-23

Test Results


The test method used?: Laboratory Resistivity Test for Soil
Input Type: Measured
Tester's full name: Vincent Onoh
Date of test: 01/06/2015
Soil sample resistance (lab measure 1): 3600 Ohms
Soil sample resistance (lab measure 2): 3700 Ohms
Soil sample resistance (lab measure 3): no data Ohms
Soil sample resistance (lab measure 4): no data Ohms
Soil sample resistance (lab measure 5): no data Ohms
Soil sample resistance (lab measure 6): no data Ohms
Soil sample resistance (lab measure 7): no data Ohms
Soil sample resistance (lab measure 8): no data Ohms
Soil sample resistance (lab measure 9): no data Ohms
Soil sample resistance (lab measure 10): no data Ohms
Soil sample resistance (lab measure 11): no data Ohms
Soil sample resistance (lab measure 12): no data Ohms
Minimum soil resistance of the lab measurement: 3600 Ohms
Soil sample temperature: 19.7 C
Soil box constant: 1
pH of soil: 8.66
Minimum soil resistance corrected to 15.5: 3978 Ohms
Minimum soil resistivity at 15.5: 3978 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/23/2015