Summary for Test 2020-08-17-23-4

Test performed: AASHTO T315-16

Project Information

Project IdentifiersProject ID: 213887
DEA: 024H2604
EFIS: 0218000100
DIST-CO-RTE-PM02-SIS-97-R11.5/17.1
Award Date03/15/2019
Closeout Date01/04/2021
Work DescriptionCOLD PLANE AC, REPLACE AC SURFACING, PLACE AC, RUMBLE STRIP & STRIPE.
Location DescriptionSISKIYOU COUNTY ABOUT 12 MILES NORTH OF WEED FROM YELLOW BUTTE ROAD TO 0.6 MILE NORTH OF DEER MOUNTAIN ROAD
QA Service Level1 (Verified on 04/03/2019)

Sample Information

Sample Taken Date08/17/2020 Sample Unique Key23
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing08/25/2020
Sample typeAcceptance A brief description of the sampleAsphalt Binder
The quantity of what the sample constitutes2 Cans, #1 Test From where was the sample collectedSource
First name of sampler or witnessed byAshton Last name of sampler or witnessed byErickson
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameAlbina - Klamath Falls, OR Transportation Laboratory (TL) Number896020
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 64-28 M
ModifiedYes Lot number
Sublot number Tank numberNot set
Time of sampleNot set HMA SupplierNot set
Certified Asphalt SupplierNot set MultigradeNot set
Multigrade TypeNot set Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2020-08-17-23
DIME Test ID: 2020-08-17-23-4
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2020-09-21

Test Results


Phase: Original binder
Input Type: Calculated
Tester's full name: Doug Ruff
Date of test: 09/16/2020
Test Plate Diameter: 25 mm
Phase Angle (δ) (for the 10 cycles): 70.3 degree
Dynamic Shear, G*/sin(δ): 2.20 kPa
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/21/2020