Summary for Test 2020-08-11-17-1

Test performed: AASHTO T240-17

Project Information

Project IdentifiersProject ID: 214654
DEA: 020J1904
EFIS: 0219000070
DIST-CO-RTE-PM02-LAS-395-R114.5/119.0
Award Date04/02/2020
Closeout Date10/22/2020
Work DescriptionPLACE HMA (TYPE A) OVERLAY, SHOULDER BACKING, AND TRAFFIC STRIPE.
Location DescriptionLASSEN COUNTY AT AND NEAR TERMO FROM 4.2 MILES NORTH OF CEMETERY ROAD TO 1.6 MILES SOUTH OF COUNTY ROAD 531
QA Service Level1 (Verified on 03/02/2020)

Sample Information

Sample Taken Date08/11/2020 Sample Unique Key17
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/19/2020
Sample typeAcceptance A brief description of the sampleAB #1 test received 1st sample, #2(996931), #3(891905) No Test
The quantity of what the sample constitutes1 From where was the sample collectedSource
First name of sampler or witnessed byj Last name of sampler or witnessed bydelejade
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameEagle Peak Transportation Laboratory (TL) Number897714
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 64-28 M
ModifiedYes Lot number
Sublot number Tank numberNot set
Time of sampleNot set HMA SupplierNot set
Certified Asphalt SupplierNot set MultigradeNot set
Multigrade TypeNot set Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2020-08-11-17
DIME Test ID: 2020-08-11-17-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2020-09-18

Test Results


Is mass change based on one or two containers?: One
Input Type: Measured
Tester's full name: Ruben Macias
Date of test: 08/20/2020
Any material loss from containers during heating process/testing?: No
Mass of empty container #1: 173.730 grams
Mass of container #1 before test (m1i): 208.650 grams
Mass of container #1 after test (m1f): 208.540 grams
Average mass change: -0.315 percent
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/18/2020