Summary for Test 2020-06-11-57-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 213887
DEA: 024H2604
EFIS: 0218000100
DIST-CO-RTE-PM02-SIS-97-R11.5/17.1
Award Date03/15/2019
Closeout Date01/04/2021
Work DescriptionCOLD PLANE AC, REPLACE AC SURFACING, PLACE AC, RUMBLE STRIP & STRIPE.
Location DescriptionSISKIYOU COUNTY ABOUT 12 MILES NORTH OF WEED FROM YELLOW BUTTE ROAD TO 0.6 MILE NORTH OF DEER MOUNTAIN ROAD
QA Service Level1 (Verified on 04/03/2019)

Sample Information

Sample Taken Date06/11/2020 Sample Unique Key57
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/11/2020
Sample typeVerification A brief description of the sample1/2-inch Type A Untreated Virgin Aggregate
The quantity of what the sample constitutesJMF From where was the sample collectedSource
First name of sampler or witnessed byAshton Last name of sampler or witnessed byErickson
Title of samplerRMC QC Telephone number of sampler
Laboratory sample identificationD78473F Linked DIME Sample ID
The fabricator/manufacturer/facility nameTruax Quarry Transportation Laboratory (TL) Number990768
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-47-0037
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedLab-Batched from Sized Untreated Aggregate Stockpiles
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design numberJMF 19-24-S3 Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-06-11-57
DIME Test ID: 2020-06-11-57-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2020-09-17

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): Yes
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: Ward Jenkins
Date of test: 09/15/2020
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 100 %
Cumulative percent passing the 1/2 in. sieve: 98 %
Cumulative percent passing the 3/8 in. sieve: 90.9 %
Cumulative percent passing the 1/4 in. sieve: 77.5 %
Cumulative percent passing the #4 sieve: 61.8 %
Cumulative percent passing the #8 sieve: 35.5 %
Cumulative percent passing the #16 sieve: 23.2 %
Cumulative percent passing the #30 sieve: 16.1 %
Cumulative percent passing the #50 sieve: 11.7 %
Cumulative percent passing the #100 sieve: 8.5 %
Cumulative percent passing the #200 sieve: 6.12 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/17/2020