Test 2020-09-10-1-5 (ASTM A970-15e1) Summary

Project Information
Project IdentifiersProject ID: 208973
DEA: 120H1004
EFIS: 1200000180
COOP: 120670
DIST-CO-RTE-PM12-ORA-405,73,405,605-9.3/24.3
Work Description(Alternative Delivery) San Diego Freeway (I-405) Improvement Project SR-73 to I-605, Design Build Project, Administered by Orange County Transportation Authority, Caltrans METS to perform Source Inspection per RFP.
Location DescriptionOrange and Los Angeles Counties: 12-ORA-405 PM 9.3/24.2 / 07-LA-405 PM 0.0/1.2 12-ORA-22 PM R0.7/R3.8 / 12-ORA-22 PM R0.5/R0.7 12-ORA-73 PM R27.2/R27.8 / 12-ORA-605 PM 3.5/R1.6 07-LA-605 PM R0.0/R1.2
Sample Information
Sample Taken Date9/10/2020 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing9/14/2020
Sample typeQuality Assurance A brief description of the sample#5 HRC 120 T-Heads
The quantity of what the sample constitutes1860 headed bars From where was the sample collectedSource
First name of sampler or witnessed byMichael Last name of sampler or witnessed byCattabiani
Title of samplerAsst METS Rep Laboratory sample identification
The fabricator/manufacturer/facility nameHRC Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)3095015 Head Manufacturer Lot Number(s)100103796
Rebar Size#5 Headed Bar Model NameHRC 120
Size of HeadFull Size - 9x Head Connection TypeFriction Weld
Head ShapeSquare Rebar ManufacturerCMC Steel California
Head ManufacturerHRC Head FabricatorHRC
Material Standard CodeASTM A706
Test Details
DIME Sample ID: 2020-09-10-1
DIME Test ID: 2020-09-10-1-5
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2020-09-15
Test Results

Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 09/15/2020
UTM: 400kip
Temperature:72 f
NumLot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
1380.312946895059OK Neckingfsaylor

General comments (publicly viewable) (Max 1000 characters): OK Necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 09/15/2020