Summary for Test 2020-08-04-18-2

Test performed: AASHTO T51-13

Project Information

Project IdentifiersProject ID: 214777
DEA: 100H5604
EFIS: 1013000148
DIST-CO-RTE-PM10-SJ-26-13.1/R13.8
Award Date04/22/2020
Closeout Date12/07/2020
Work DescriptionSJ26 WIDENING
Location DescriptionSAN JOAQUIN COUNTY NEAR LINDEN FROM 0.5 MILE EAST OF FINE ROAD TO 1.3 MILES WEST OF ESCALON-BELLOTA ROAD
QA Service Level1 (Verified on 03/30/2020)

Sample Information

Sample Taken Date08/04/2020 Sample Unique Key18
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/07/2020
Sample typeAcceptance A brief description of the samplePG 64-16 #1 test
The quantity of what the sample constitutes 1 can,each #1test,#2(033961-2), #3(034759), #4(034761) No test From where was the sample collectedSource
First name of sampler or witnessed byJ Last name of sampler or witnessed bydehoff
Title of samplerinspector Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameWestern Refining-marathon elk grove Transportation Laboratory (TL) Number033961-1
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
ModifiedNo Lot number1
Sublot number2 Tank numberNot set
Time of sampleNot set HMA SupplierNot set
Certified Asphalt SupplierNot set MultigradeNot set
Multigrade TypeNot set Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2020-08-04-18
DIME Test ID: 2020-08-04-18-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T51-13: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Test Release Date: 2020-09-21

Test Results


Is a normal test obtainable?: Yes
Number of replicates tested: One
Input Type: Measured
Tester's full name: Ruben Macias
Date of test: 09/14/2020
Ductility of test #1 (D1): 100 cm
Ductility of sample: 100 cm
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/21/2020