Summary for Test 2020-09-01-5-1
Test performed: AASHTO T59-16Project Information
Project Identifiers | Project ID: 212535 DEA: 031A9204 EFIS: 0300020608 |
---|---|
DIST-CO-RTE-PM | 03-SUT-20-5-11.3 |
Award Date | 06/11/2019 |
Closeout Date | 12/01/2021 |
Work Description | SUTTER BYPASS WIDENING AND REHAB |
Location Description | NEAR YUBA CITY FROM SUTTER BYPASS TO 0.1 MILE WEST OF LYTLE ROAD. |
QA Service Level | 1 (Verified on 07/23/2018) |
Sample Information
Sample Taken Date | 09/01/2020 | Sample Unique Key | 5 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/01/2020 |
Sample type | Acceptance | A brief description of the sample | Tack oil ss-1h |
The quantity of what the sample constitutes | 1 jug | From where was the sample collected | Job Site |
First name of sampler or witnessed by | T | Last name of sampler or witnessed by | Granados |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Pacific Northwest Oil - Stockton, CA | Transportation Laboratory (TL) Number | 779032 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphaltic Emulsion | Emulsion Grade | SS-1h |
---|---|---|---|
Lot Number | Not set | Sub Lot | Not set |
Test Details
DIME Sample ID: 2020-09-01-5
DIME Test ID: 2020-09-01-5-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T59-16: Standard Method of Test for Emulsified Asphalts (Residue and Oil Distillate (Sec. 6))
Test Release Date: 2020-09-10
Test Results
What parameters are being calculated?: Percentage of oil residue
Is this a polymer-modified emulsion: No
Input Type: Measured
Tester's full name: Eva Torres
Date of test: 09/10/2020
Mass of the distillation pot, accessories, and reside after the test: 2401.5 g
Mass of distillation pot and accessories before test: 2287.4 g
Correction Factor: 1.5
Mass of the distallation pot, accessories, and reside after the test w/ correction factor: 2403.0 g
Percentage of oil residue: 57.8 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/10/2020 ✔