Summary for Test 2020-08-26-15-2

Test performed: ASTM C39-10

Project Information

Project IdentifiersProject ID: 214465
DEA: 081E5704
EFIS: 0814000051
DIST-CO-RTE-PM08-RIV-10-27.7
Award Date12/26/2019
Closeout Date09/15/2021
Work DescriptionPLACE CIDH PILING AND ROCK SLOPE PROTECTION
Location DescriptionRIVERSIDE COUNTY NEAR PALM SPRINGS AT WHITEWATER RIVER BRIDGE
QA Service Level1 (Verified on 02/28/2020)

Sample Information

Sample Taken Date08/26/2020 Sample Unique Key15
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/27/2020
Sample typeQuality Control A brief description of the sample6x12
The quantity of what the sample constitutes6 From where was the sample collectedJob Site
First name of sampler or witnessed byshaki Last name of sampler or witnessed byA
Title of samplerstr rep Telephone number of sampler
Laboratory sample identification1016-69 Linked DIME Sample ID
The fabricator/manufacturer/facility namenp Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design number20045r
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected1
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedsite Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2020-08-26-15
DIME Test ID: 2020-08-26-15-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2020-09-09

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Jose Guzman
Date of test: 09/09/2020
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 6.01 in
Maximum load on cylinder 1: 120720 lb
Maximum load on cylinder 2: 1219000 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 14 days
Cross sectional area of cylinder 1: 28.37 in^2
Cross sectional area of cylinder 2: 28.37 in^2
Compressive strength of cylinder 1: 4255.2 psi
Compressive strength of cylinder 2: 42967.9 psi
Compressive strength (to nearest 10 psi): 23610 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/9/2020