Test 2020-09-01-10-1 (AASHTO T59-16) Summary

Project Information
Project IdentifiersProject ID: 215041
DEA: 031J1904
EFIS: 0320000169
DIST-CO-RTE-PM03-YUB-70,99-
Work DescriptionIn-kind restoration pvmt. repair w/HMA medium overlay, striping, traffic control, incidental work
Location DescriptionYubat & Sutter Counties at various locaitons
Sample Information
Sample Taken Date9/1/2020 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing9/2/2020
Sample typeAcceptance A brief description of the sampleAshalt Emulsion
The quantity of what the sample constitutes1 jug From where was the sample collectedJob Site
First name of sampler or witnessed byAlex Last name of sampler or witnessed byWelsh
Title of samplerInspector Laboratory sample identification
The fabricator/manufacturer/facility nameVSS Emultech Transportation Laboratory (TL) Number788962
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAsphaltic Emulsion Emulsion GradeSS-1h
Lot NumberNot set Sub LotNot set
Test Details
DIME Sample ID: 2020-09-01-10
DIME Test ID: 2020-09-01-10-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T59-16: Standard Method of Test for Emulsified Asphalts (Residue and Oil Distillate (Sec. 6))
Test Release Date: 2020-09-08
Test Results

What parameters are being calculated?: Percentage of oil residue
Is this a polymer-modified emulsion: No
Input Type: Measured
Tester's full name: Eva Torres
Date of test: 09/03/2020
Mass of the distillation pot, accessories, and reside after the test: 2186.4 g
Mass of distillation pot and accessories before test: 2070.3 g
Correction Factor: 1.5
Mass of the distallation pot, accessories, and reside after the test w/ correction factor: 2187.9 g
Percentage of oil residue:58.8 %
General comments (publicly viewable) (Max 1000 characters): Sample was almost solid and set up when opened at the lab.

Test was verified on 09/08/2020