Summary for Test 2020-08-29-6-3

Test performed: ASTM D5329-16

Project Information

Project IdentifiersProject ID: 212535
DEA: 031A9204
EFIS: 0300020608
DIST-CO-RTE-PM03-SUT-20-5-11.3
Award Date06/11/2019
Closeout Date12/01/2021
Work DescriptionSUTTER BYPASS WIDENING AND REHAB
Location DescriptionNEAR YUBA CITY FROM SUTTER BYPASS TO 0.1 MILE WEST OF LYTLE ROAD.
QA Service Level1 (Verified on 07/23/2018)

Sample Information

Sample Taken Date08/29/2020 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/01/2020
Sample typeAcceptance A brief description of the sampleARB 2 cans each, #10Test, No Test #6(766362), #7(766371), #8(766373),
The quantity of what the sample constitutes2 can of each sample From where was the sample collectedSource
First name of sampler or witnessed byE Last name of sampler or witnessed byChavez
Title of samplerTET Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameValero Transportation Laboratory (TL) Number766363
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Rubber Binder Asphalt modifier supplier
Performance GradePG 64-16 Lot number
Sublot number Asphalt Rubber Binder Mix NumberNot set

Test Details

DIME Sample ID: 2020-08-29-6
DIME Test ID: 2020-08-29-6-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Test Release Date: 2020-09-08

Test Results


Input Type: Measured
Tester's full name: Minoo Ahmadi
Date of test: 09/02/2020
Temperature: 25 C
Final Dial reading (F1): 76 mm
Ball Penetration (P1): 0 mm
Final Dial reading (F2): 77 mm
Ball Penetration (P2): 0 mm
Final Dial reading (F3): 76 mm
Ball Penetration (P3): 0 mm
Resilience 1: 24 %
Resilience 2: 23 %
Resilience 3: 24 %
Average Resilience: 24 %
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/8/2020