Test 2020-08-19-23-5 (ASTM D4791-10) Summary

Project Information
Project IdentifiersProject ID: 214756
DEA: 050N7AU4
EFIS: 0520000030
DIST-CO-RTE-PM05-SB-101-1.4/4.8
Work DescriptionSegment 4A - Carpinteria: Construct HOV lanes and rehabilitation. Source inspection of sign structure trusses, lighting structures, epoxy coated rebar, precast box culverts, precast RCP.
Location DescriptionCARPINTERIA FROM 0.2 MILE SOUTH OF BAILARD AVENUE OVERCROSSING TO 0.7 MILE SOUTH OF SOUTH PADARO LANE
Sample Information
Sample Taken Date8/19/2020 Sample Unique Key23
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing8/21/2020
Sample typeVerification A brief description of the sampleBags of Untreated Aggregate
The quantity of what the sample constitutesOne JMF Verificatioin From where was the sample collectedManufacturer
First name of sampler or witnessed byD Last name of sampler or witnessed byLaChaine
Title of sampler Laboratory sample identification
The fabricator/manufacturer/facility nameGranite Santa Paula Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-19-0046
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedAt the Plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number JMF Verification ID JMF3513-2020-196
Test Details
DIME Sample ID: 2020-08-19-23
DIME Test ID: 2020-08-19-23-5
Testing Lab: CT D05 - Field Laboratory
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Test Release Date: 2020-09-02
Test Results

Method A - Percentage of Flat Particles, Elongated Particles, and Flat & Elongated Particles
Method B - Flat & Elongated Particles

Method: B
Determination: By Mass
Dimensional ratio used: 5:1
Input Type: Calculated
Tester's full name: Daniel Gingras
Date of test: 09/01/2020
Weighted percentage of particles (by mass) that were flat and elongated:0 %
Weighted percentage of particles (by mass) that were not flat and elongated:100 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 09/02/2020