Summary for Test 2020-07-08-21-3

Test performed: AASHTO T315-16

Project Information

Project IdentifiersProject ID: 214555
DEA: 020J1204
EFIS: 0219000063
DIST-CO-RTE-PM02-SIS-89-7.0/14.0
Award Date01/31/2020
Closeout Date10/06/2020
Work DescriptionHMA OVERLAY WITH REPLACE CONCRETE ASPHALT SURFACING, SHOULDER BACKING.
Location DescriptionSISKIYOU COUNTY AT AND NEAR BARTLE FROM 2.4 MILES NORTH OF BARTLE GAP ROAD TO 0.3 MILE SOUTH OF MILITARY PASS ROAD
QA Service Level1 (Verified on 01/22/2020)

Sample Information

Sample Taken Date07/08/2020 Sample Unique Key21
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/14/2020
Sample typeAcceptance A brief description of the sampleAsphalt Binder
The quantity of what the sample constitutes4 cans, #1 TEST (990666) From where was the sample collectedSource
First name of sampler or witnessed byRandy Last name of sampler or witnessed byUnknown
Title of samplerCGI Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameValero - Benicia Transportation Laboratory (TL) Number990666
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 58-34 M
ModifiedYes Lot number
Sublot number Tank numberNot set
Time of sampleNot set HMA SupplierNot set
Certified Asphalt SupplierNot set MultigradeNot set
Multigrade TypeNot set Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2020-07-08-21
DIME Test ID: 2020-07-08-21-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2020-08-31

Test Results


Phase: RTFO residue
Input Type: Calculated
Tester's full name: Eva Torres
Date of test: 08/31/2020
Test Plate Diameter: 25 mm
Phase Angle (δ) (for the 10 cycles): 60.1 degree
Dynamic Shear, G*/sin(δ): 7.60 kPa
General comments (publicly viewable) (Max 1000 characters): At 64 C Phase angle =61.5 and G*/sin(phase angle) = 4.20

Test was verified on 8/31/2020