Test 2020-07-29-41-1 (CTM 643-April 2020) Summary

Project Information
Project IdentifiersProject ID: 215119
DEA: 020J4604
EFIS: 0219000126
DIST-CO-RTE-PM02-TEH-36-
Work DescriptionLeftover Culverts
Location DescriptionNot set
Sample Information
Sample Taken Date7/29/2020 Sample Unique Key41
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing8/6/2020
Sample typeInformational A brief description of the sampleSand, Silt, Rock
The quantity of what the sample constitutesnot provided From where was the sample collectedJob Site
First name of sampler or witnessed byDan Last name of sampler or witnessed byCurran
Title of sampler Laboratory sample identificationD78545
The fabricator/manufacturer/facility nameNot Provided Transportation Laboratory (TL) Number897733
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeSoil The fabricator's/manufacturer's product name for the sample
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collectedTeh 36 PM 9.63
Where the material sample would have been placed if not sampled
Test Details
DIME Sample ID: 2020-07-29-41
DIME Test ID: 2020-07-29-41-1
Testing Lab: CT D02 - North Region Materials Lab
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2020-08-25
Test Results

The test method used?: Laboratory Resistivity Test for Soil
Input Type: Measured
Tester's full name: Terry McCormick
Date of test: 08/06/2020
Minimum soil resistance of the lab measurement: 3300 Ohms
Soil sample temperature: 19.2 C
Soil box constant: 1
pH of soil: 7.00
Minimum soil resistance corrected to 15.5: 3605.25 Ohm-cm
Minimum soil resistivity at 15.5:3605 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 08/25/2020