Summary for Test 2020-08-18-17-2

Test performed: ASTM F606-14

Project Information

Project IdentifiersProject ID: 88888
DEA: SMTL-STOCK
EFIS: SMTL-STOCK
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date08/18/2020 Sample Unique Key17
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/20/2020
Sample typeQuality Assurance A brief description of the sampleA449 All Thread
The quantity of what the sample constitutes12 From where was the sample collectedFabricator
First name of sampler or witnessed byDong Last name of sampler or witnessed byShin
Title of samplerQA Inspector Telephone number of sampler205-999-5798
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameUIS Lindon UT Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB314-050-20 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)10627830 Nut Mfg. Lot Number(s)
Washer Mfg. Lot Number(s) Bolt SpecificationA449
Bolt Length(s)12" Nut Specificationna
Washer Specificationna FinishHDG
Diameter/Size5/8" Bolt Mfg. Lot Number
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2020-08-18-17
DIME Test ID: 2020-08-18-17-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2020-08-25

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 08/24/2020
UTM: 400kip
Temperature: 72
NumSampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
11BUNC 5/8 0.2263070213613584712012627148A449 Tensile

General comments (publicly viewable) (Max 1000 characters): A449 Tensile
Test Graph
Source: Bluehill Data Point File

Test was verified on 8/25/2020