Summary for Test 2020-06-24-36-4

Test performed: AASHTO T315-16

Project Information

Project IdentifiersProject ID: 213411
DEA: 030H10U4
EFIS: 0317000246
DIST-CO-RTE-PM03-SAC-5-9.7/24.9
Award Date05/01/2019
Closeout Date02/22/2024
Work DescriptionNot set
Location DescriptionConstruction on state highway in Sacramento County in and near Sacramento from 1.1 miles south of Elk Grove Boulevard to American River Viaduct
QA Service Level1 (Verified on 07/19/2019)

Sample Information

Sample Taken Date06/24/2020 Sample Unique Key36
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/16/2020
Sample typeAcceptance A brief description of the sampleTEST Asphalt Binder
The quantity of what the sample constitutes4 cans each, #10 TEST (#7 765681, #8 723333, #9 060127) From where was the sample collectedSource
First name of sampler or witnessed byLuke Last name of sampler or witnessed byBaptista
Title of samplerInspector Telephone number of sampler530-812-7116
Laboratory sample identification Linked DIME Sample IDAB206051
The fabricator/manufacturer/facility namePacific Northwest Oil - Stockton, CA Transportation Laboratory (TL) Number060128
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
ModifiedNo Lot number
Sublot number Tank numberNot set
Time of sampleNot set HMA SupplierNot set
Certified Asphalt SupplierNot set MultigradeNot set
Multigrade TypeNot set Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2020-06-24-36
DIME Test ID: 2020-06-24-36-4
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2020-08-20

Test Results


Phase: RTFO residue
Input Type: Calculated
Tester's full name: Eva Torres
Date of test: 08/19/2020
Test Plate Diameter: 25 mm
Phase Angle (δ) (for the 10 cycles): 84.2 degree
Dynamic Shear, G*/sin(δ): 3.53 kPa
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/20/2020