Summary for Test 2020-08-10-29-3

Test performed: CTM 229-June 2011

Project Information

Project IdentifiersProject ID: 212630
DEA: 022H6304
EFIS: 0216000156
DIST-CO-RTE-PM02-TEH-36-26.6/27.6
Award Date06/19/2020
Closeout Date01/05/2021
Work DescriptionDIAMOND STAR CURVE
Location DescriptionTEHAMA COUNTY ABOUT 14 MILES WEST OF RED BLUFF FROM 0.3 MILE WEST OF BASLER ROAD TO 0.1 MILE EAST OF DIAMOND STAR ROAD
QA Service Level1 (Verified on 08/10/2017)

Sample Information

Sample Taken Date08/10/2020 Sample Unique Key29
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/10/2020
Sample typeQuality Assurance A brief description of the sample3/4" Class II AB
The quantity of what the sample constitutesnot provided From where was the sample collectedJob Site
First name of sampler or witnessed byDave Last name of sampler or witnessed byLockett
Title of sampler Telephone number of sampler
Laboratory sample identificationD78563 Linked DIME Sample ID
The fabricator/manufacturer/facility nameNorthstate Asphalt Transportation Laboratory (TL) Number002343
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Tullis - Northstate Asphalt
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedWindrow
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-08-10-29
DIME Test ID: 2020-08-10-29-3
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 229-June 2011: Method of Test for Durability Index
Test Release Date: 2020-08-19

Test Results


What test(s) are being run?: Coarse durability and fine durability
Input Type: Measured
Tester's full name: Terry McCormick
Date of test: 08/13/2020
Sediment reading for coarse durability index: 13
Clay reading: 5.8
Sand reading: 3.8
Coarse durability index: 70
Fine durability index: 66
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/19/2020