Summary for Test 2020-08-12-2-4

Test performed: AASHTO T84-14

Project Information

Project IdentifiersProject ID: 213764
DEA: 080F0304
EFIS: 0800020358
DIST-CO-RTE-PM08-SBD-60-R0.7/R3.0
Award Date03/07/2019
Closeout Date07/27/2023
Work DescriptionREMOVE AND REPLACE THREE OVERCROSSING BRIDGES ON ROUTE 60
Location DescriptionIN SAN BERNARDINO COUNTY IN AND NEAR CHINO AT VARIOUS LOCATIONS FROM O.1 MILE WEST OF PIPELINE AVENUE OVERCROSSING TO 0.1 MILE EAST OF BENSON AVENUE OVERCROSSING
QA Service Level1 (Verified on 05/01/2019)

Sample Information

Sample Taken Date08/12/2020 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/12/2020
Sample typeVerification A brief description of the samplePSUE 3/4" HMA-A-SP, R15 0.5% LAS
The quantity of what the sample constitutes2 Bags Of Coldfeed Agg., 1 Bag Of Rap From where was the sample collectedManufacturer
First name of sampler or witnessed byEdmond Last name of sampler or witnessed byJabbour
Title of sampler Telephone number of sampler
Laboratory sample identification0495A-20 Linked DIME Sample ID
The fabricator/manufacturer/facility nameRJ Noble Company Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0039
The fabricator's/manufacturer's product name for the sample3/4 HMA-A-SP R15 The fabricator/manufacturer designation for the sample
The plant number36R1504SPWC A detailed description of where the material sample was collectedBelt Cut at RJ Noble Corona Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-08-12-2
DIME Test ID: 2020-08-12-2-4
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2020-08-19

Test Results


Input Type: Measured
Tester's full name: Sebastian Ferrer
Date of test: 08/14/2020
Mass of saturated surface dry sample (before pycnometer) (S): 500 grams
Mass of the pycnometer with water and aggregate (C): 962.6 grams
Mass of the pycnometer with water (B): 653.3 grams
Mass of the oven dried sample (before pycnometer) (A): 489.6 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500 grams
Mass of the oven dry aggregate (for absorption) (A): 489.6 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity: 2.567
Bulk specific gravity (SSD Basis): 2.622
Apparent specific gravity: 2.715
Absorption: 2.1 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/19/2020