Summary for Test 2020-08-07-18-5
Test performed: ASTM D4791-10Project Information
Project Identifiers | Project ID: 212618 DEA: 044G0564 EFIS: 0417000154 |
---|---|
DIST-CO-RTE-PM | 04-ALA-680-M2.4/M12.4 |
Award Date | 11/16/2017 |
Closeout Date | 12/08/2022 |
Work Description | ROADWAY REHAB, BRIDGE REPLACEMENT, RET. WALLS, TOLL SYSTEMS |
Location Description | FREMONT AND AT SUNOL FROM MISSION BOULEVARD SEPARATION TO KOOPMAN ROAD UNDERCROSSING |
QA Service Level | 1 (Verified on 10/16/2017) |
Sample Information
Sample Taken Date | 08/07/2020 | Sample Unique Key | 18 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | Not set |
Sample type | Verification | A brief description of the sample | 1/2" virgin aggregate |
The quantity of what the sample constitutes | 2 bags | From where was the sample collected | Source |
First name of sampler or witnessed by | Dennis | Last name of sampler or witnessed by | Yeung |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Hanson Sunol | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-01-0011 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Hanson Sunol Plant | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1/2 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2020-08-07-18
DIME Test ID: 2020-08-07-18-5
Testing Lab: CT D04 - Hayward DME / District Laboratory
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Test Release Date: 2020-08-18
Test Results
Method A - Percentage of Flat Particles, Elongated Particles, and Flat & Elongated Particles
Method B - Flat & Elongated Particles
Method: A
Determination: By Number
Dimensional ratio used: 5:1
Input Type: Calculated
Tester's full name: Nicholas Shelly
Date of test: 08/12/2020
Weighted percentage of particles (by number) that were flat: 0 %
Weighted percentage of particles (by number) that were elongated: 0 %
Weighted percentage of particles (by number) that were both flat and elongated: 0 %
Weighted percentage of particles (by number) that were neither flat nor elongated: 100 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/18/2020 ✔