Summary for Test 2020-08-02-1-2
Test performed: ASTM D36-14ε1Project Information
Project Identifiers | Project ID: 214528 DEA: 024G5404 EFIS: 0214000024 |
---|---|
DIST-CO-RTE-PM | 02-TEH-36-40.3/42.1 |
Award Date | 01/08/2020 |
Closeout Date | 09/15/2021 |
Work Description | PLACE HMA AND MINOR CONCRETE, AND MODIFY ELECTRICAL SYSTEM. |
Location Description | TEHAMA COUNTY IN RED BLUFF FROM 0.6 MILE EAST OF BAKER ROAD TO 0.2 MILE EAST OF EAST SAND SLOUGH BRIDGE |
QA Service Level | 1 (Verified on 01/22/2020) |
Sample Information
Sample Taken Date | 08/02/2020 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/05/2020 |
Sample type | Acceptance | A brief description of the sample | Asphalt Binder |
The quantity of what the sample constitutes | 1 can, NO Test #2(815627),#3(815628) | From where was the sample collected | Source |
First name of sampler or witnessed by | C | Last name of sampler or witnessed by | Bryant |
Title of sampler | TET | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Valero - Benicia | Transportation Laboratory (TL) Number | 853446-1 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Rubber Binder | Asphalt modifier supplier | |
---|---|---|---|
Performance Grade | PG 64-16 | Lot number | |
Sublot number | Asphalt Rubber Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2020-08-02-1
DIME Test ID: 2020-08-02-1-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Test Release Date: 2020-08-17
Test Results
ASTM Thermometer used?: C
Input Type: Measured
Tester's full name: Juan Gomez
Date of test: 08/14/2020
Softening Point Sample 1: 72 C
Softening Point Sample 2: 72 C
Bath Liquid: freshly boiled distilled water
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/17/2020 ✔