Summary for Test 2020-06-04-33-3
Test performed: AASHTO T209-12Project Information
Project Identifiers | Project ID: 214571 DEA: 020J1104 EFIS: 0219000062 |
---|---|
DIST-CO-RTE-PM | 02-PLU-70-33.1/42.1 |
Award Date | 02/07/2020 |
Closeout Date | 04/27/2021 |
Work Description | PLACE HMA & SHOULDER BACKING, & REMOVE & REPLACE PAVEMENT DELINEATION. |
Location Description | PLUMAS COUNTY AT AND NEAR KEDDIE FROM INDIAN CREEK BRIDGE TO 0.3 MILE WEST OF SPANISH CREEK BRIDGE NO. 09-0018 |
QA Service Level | 1 (Verified on 01/22/2020) |
Sample Information
Sample Taken Date | 06/04/2020 | Sample Unique Key | 33 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/05/2020 |
Sample type | Verification | A brief description of the sample | Combined RAP (1/2-inch) |
The quantity of what the sample constitutes | JMF Verification | From where was the sample collected | Source |
First name of sampler or witnessed by | PEI | Last name of sampler or witnessed by | PEI |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | D78457B | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Sierra Cascade Aggregate and Asphalt Products | Transportation Laboratory (TL) Number | 733198 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Reclaimed Asphalt Pavement | RAP Source | Sierra Cascade |
---|---|---|---|
Aggregate Size | 1/2-inch | Aggregate Source | |
RAP Stockpile | Stockpile Size (tons) | ||
Reclaimed Asphalt Pavement Mix Number | Not set |
Test Details
DIME Sample ID: 2020-06-04-33
DIME Test ID: 2020-06-04-33-3
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2020-08-15
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Karen Spliethof
Date of test: 06/06/2020
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7338.0 grams
Mass of oven-dry sample in air for Sample 1: 1535.0 grams
Mass of container filled with the sample and water for Sample 1: 8262.0 grams
Temperature of Water: 76 °F
Specific Gravity for Sample 1: 2.509
Theoretical maximum density at 25°C (77°F): no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/15/2020 ✔