Summary for Test 2020-07-17-25-2

Test performed: AASHTO T51-13

Project Information

Project IdentifiersProject ID: 209520
DEA: 06470904
EFIS: 0600000973
COOP: 061529
DIST-CO-RTE-PM06-MAD-99-R7.5/15.1
Award Date03/14/2019
Closeout Date05/11/2023
Work DescriptionWIDEN FREEWAY FROM 4 LANES TO 6 LANES.
Location DescriptionMADERA COUNTY IN AND NEAR MADERA FROM AVENUE 12 OVERCROSSING TO 0.9 MILE NORTH OF AVENUE 17 OVERCROSSING
QA Service Level1 (Verified on 03/16/2016)

Sample Information

Sample Taken Date07/17/2020 Sample Unique Key25
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/23/2020
Sample typeAcceptance A brief description of the sampleAsphalt Binder PG 70-10
The quantity of what the sample constitutes4 Cans each, TEST #20 (#19 027517, #21 027528), #22(039484) From where was the sample collectedSource
First name of sampler or witnessed byM Last name of sampler or witnessed byShirvani
Title of samplerTE Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameSan Joaquin Refinery Transportation Laboratory (TL) Number027522
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 70-10
ModifiedNo Lot number
Sublot number Tank numberNot set
Time of sampleNot set HMA SupplierNot set
Certified Asphalt SupplierNot set MultigradeNot set
Multigrade TypeNot set Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2020-07-17-25
DIME Test ID: 2020-07-17-25-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T51-13: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Test Release Date: 2020-09-29

Test Results


Is a normal test obtainable?: Yes
Number of replicates tested: One
Input Type: Measured
Tester's full name: Sunday Agude
Date of test: 07/31/2020
Ductility of test #1 (D1): 100 cm
Ductility of sample: 100 cm
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/29/2020