Summary for Test 2020-07-21-16-2
Test performed: AASHTO T51-13Project Information
Project Identifiers | Project ID: 212899 DEA: 051C6704 EFIS: 0512000194 |
---|---|
DIST-CO-RTE-PM | 05-SCR-17-0.2-0.5 |
Award Date | 02/08/2019 |
Closeout Date | 09/23/2022 |
Work Description | PASATIEMPO RETAINING WALL - |
Location Description | IN SANTA CRUZ FROM 0.5 MILE TO 0.3 MILES SOUTH OF PASATIEMPO OVERCROSSING |
QA Service Level | 1 (Verified on 04/01/2019) |
Sample Information
Sample Taken Date | 07/21/2020 | Sample Unique Key | 16 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/28/2020 |
Sample type | Acceptance | A brief description of the sample | TEST Asphalt Binder PG 64-16 |
The quantity of what the sample constitutes | 1 can, #1 TEST | From where was the sample collected | Source |
First name of sampler or witnessed by | L | Last name of sampler or witnessed by | Amparan |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | San Joaquin Refinery | Transportation Laboratory (TL) Number | 972754 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 64-16 |
---|---|---|---|
Modified | No | Lot number | 1 |
Sublot number | 1 | Tank number | Not set |
Time of sample | Not set | HMA Supplier | Not set |
Certified Asphalt Supplier | Not set | Multigrade | Not set |
Multigrade Type | Not set | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2020-07-21-16
DIME Test ID: 2020-07-21-16-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T51-13: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Test Release Date: 2020-09-24
Test Results
Is a normal test obtainable?: Yes
Number of replicates tested: One
Input Type: Measured
Tester's full name: Sunday Agude
Date of test: 07/31/2020
Ductility of test #1 (D1): 100 cm
Ductility of sample: 100 cm
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/24/2020 ✔