Summary for Test 2020-07-24-33-3

Test performed: AASHTO T84-14

Project Information

Project IdentifiersProject ID: 214289
EFIS: 0000001157
Permit Numbers: 0514NMC0478 0519NRT0383 0519NRT0001 0519NRD0572
DIST-CO-RTE-PM05---6.9
Award Date01/05/2018
Closeout Date08/23/2021
Work DescriptionReference Permit #0514-NMC-0478 on all correspondence. Note #0519-NRT-0383 is just a time extension for the original permit. Work Desc: Widen Blosser Road to provide a right turn lane for the northbound approach to West Main Street (State Route 166).
Location DescriptionW. Main Street (Hwy 166), Santa Maria
QA Service Level1 (Verified on 08/07/2019)

Sample Information

Sample Taken Date07/24/2020 Sample Unique Key33
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing07/24/2020
Sample typeVerification A brief description of the sample1/2" Virgin Aggregate
The quantity of what the sample constitutes3 bags From where was the sample collectedManufacturer
First name of sampler or witnessed bySyd Last name of sampler or witnessed byValeh
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameDutra Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-21-0008
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedDutra Richmond
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-07-24-33
DIME Test ID: 2020-07-24-33-3
Testing Lab: CT D04 - Hayward DME / District Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2020-08-11

Test Results


Input Type: Measured
Tester's full name: Nicholas Shelly
Date of test: 08/07/2020
Mass of saturated surface dry sample (before pycnometer) (S): 500 grams
Mass of the pycnometer with water and aggregate (C): 971.7 grams
Mass of the pycnometer with water (B): 662.5 grams
Mass of the oven dried sample (before pycnometer) (A): 490.3 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500 grams
Mass of the oven dry aggregate (for absorption) (A): 490.3 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity: 2.570
Bulk specific gravity (SSD Basis): 2.621
Apparent specific gravity: 2.707
Absorption: 2 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/11/2020