Summary for Test 2020-06-02-33-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 214513
DEA: 021H3904
EFIS: 0216000041
DIST-CO-RTE-PM02-SHA-5-R32.0/R32.3
Award Date01/24/2020
Closeout Date09/28/2021
Work DescriptionO'BRIEN DECK AND RAIL REHAB: WEATHER INFO SYSTEM, STRUCTURAL CONCRETE, HMA, REMOVE BRIDGE BARRIER.
Location DescriptionSHASTA COUNTY ABOUT 10 MILES SOUTH OF LAKEHEAD FROM 0.1 MILE SOUTH TO 0.3 MILE NORTH OF O'BRIEN UNDERCROSSING
QA Service Level1 (Verified on 01/22/2020)

Sample Information

Sample Taken Date06/02/2020 Sample Unique Key33
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/02/2020
Sample typeVerification A brief description of the sample1/2-inch Type A HMA (eq. PG 64-28 M) 24.0 RAP, 1.3 Lime
The quantity of what the sample constitutesJMF Verification Renewal From where was the sample collectedManufacturer
First name of sampler or witnessed byAnthony Last name of sampler or witnessed byOrtiz
Title of sampler Telephone number of sampler
Laboratory sample identificationD78451 Linked DIME Sample ID
The fabricator/manufacturer/facility nameNorthstate Asphalt, Redding, CA Transportation Laboratory (TL) Number036435
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot number
Sublot number HMA Mix NumberNot set

Test Details

DIME Sample ID: 2020-06-02-33
DIME Test ID: 2020-06-02-33-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2020-08-11

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Terry McCormick
Date of test: 08/08/2020
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1771.4 g
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): 0.48 %
Moisture Content: 0.00 %
Temperature Compensation Factor: no data
Test Temperature: 1000 F
Corrected Asphalt Binder Content: 5.38 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/11/2020