Summary for Test 2020-07-29-14-1

Test performed: AASHTO T59-16

Project Information

Project IdentifiersProject ID: 214175
DEA: 030H4804
EFIS: 0315000198
DIST-CO-RTE-PM03-SAC-99-0.1/1.6,11.8/21.6
Award Date08/20/2019
Closeout Date08/11/2023
Work DescriptionCOLD PLANE AC PAVEMENT AND RHMA OVERLAY.
Location DescriptionSACRAMENTO COUNTY IN AND NEAR GALT FROM DRY CREEK BRIDGE TO SIMMERHORN ROAD AND IN ELK GROVE AND SACRAMENTO FROM 0.9 MILE SOUTH OF ELK GROVE BOULEVARD TO MARTIN LUTHER KING JR BOULEVARD
QA Service Level1 (Verified on 05/29/2019)

Sample Information

Sample Taken Date07/29/2020 Sample Unique Key14
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/31/2020
Sample typeAcceptance A brief description of the sampleEMULSION
The quantity of what the sample constitutes1 bottle From where was the sample collectedSource
First name of sampler or witnessed bySushma Last name of sampler or witnessed byLee
Title of samplerRE Telephone number of sampler916-718-8055
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameUnknown Transportation Laboratory (TL) Number047
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphaltic Emulsion Emulsion GradeSS-1h
Lot NumberNot set Sub LotNot set

Test Details

DIME Sample ID: 2020-07-29-14
DIME Test ID: 2020-07-29-14-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T59-16: Standard Method of Test for Emulsified Asphalts (Residue and Oil Distillate (Sec. 6))
Test Release Date: 2020-08-07

Test Results


What parameters are being calculated?: Percentage of oil residue
Is this a polymer-modified emulsion: No
Input Type: Measured
Tester's full name: Sunday Agude
Date of test: 08/06/2020
Mass of the distillation pot, accessories, and reside after the test: 2290.8 g
Mass of distillation pot and accessories before test: 2174.0 g
Correction Factor: 1.5
Mass of the distallation pot, accessories, and reside after the test w/ correction factor: 2292.3 g
Percentage of oil residue: 59.2 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/7/2020