Summary for Test 2014-11-18-5-3

Test performed: CTM 229-June 2011

Project Information

Project IdentifiersProject ID: 7427
DEA: 07215934
EFIS: 0700001833
DIST-CO-RTE-PM07-LA-5-2.4/4.0
Award Date08/14/2012
Closeout Date02/20/2020
Work DescriptionWiden and Realign Freeway and Construct Ped OC, OC and UC Structures.
Location DescriptionLOS ANGELES COUNTY IN SANTA FE SPRINGS AND NORWALK FROM 0.1 MILE NORTH OF CARMENITA ROAD OVERCROSSING TO 0.1 MILE NORTH OF SILVERBOW AVENUE PEDESTRIAN OVERCROSSING
QA Service Level1 (Verified on 11/26/2012)

Sample Information

Sample Taken Date11/18/2014 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/21/2014
Sample typeAcceptance A brief description of the sampleClass 3 Aggregate Base
The quantity of what the sample constitutes2 Bags From where was the sample collectedOther
First name of sampler or witnessed byRamsey Last name of sampler or witnessed byDoumani
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identification4314B Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameI 15 South Mainline Transportation Laboratory (TL) NumberC671653
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Unknown
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedI 15 South Mainline
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size
The concrete mix design number Lot numberNot set
Sublot numberNot set Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2014-11-18-5
DIME Test ID: 2014-11-18-5-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 229-June 2011: Method of Test for Durability Index
Test Release Date: 2015-02-23

Test Results


What test(s) are being run?: Coarse durability and fine durability
Input Type: Calculated
Tester's full name: Danilo Ferrer
Date of test: 12/09/2014
Coarse durability index: 70
Fine durability index: 55
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/23/2015