Summary for Test 2020-07-31-3-2

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 212596
DEA: 100L0204
EFIS: 1013000053
DIST-CO-RTE-PM10-SJ,STA-99-0.0-0.7:24.4-24.8
Award Date11/30/2018
Closeout Date07/15/2021
Work DescriptionPartial Bridge Replacement
Location DescriptionON ROUTE 99 IN RIPON AT THE COUNTY LINE OF SAN JOAQUIN COUNTY AND STANISLAUS COUNTY AT THE STANISLAUS RIVER BRIDGES (29-0013L/R).
QA Service Level1 (Verified on 12/19/2018)

Sample Information

Sample Taken Date07/31/2020 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/06/2020
Sample typeQuality Assurance A brief description of the sampleA325 ROCAP ASSEMBLY
The quantity of what the sample constitutes755 From where was the sample collectedFabricator
First name of sampler or witnessed byMahlon Last name of sampler or witnessed byLindenmuth
Title of samplerQA Inspector Telephone number of sampler646-740-3704
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameUtah Pacific Bridge and Steel Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormS46-630-20 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)U88982
Heat Number(s)Bolt DL18107414 Nut 75076196 Washer 182006 Nut Mfg. Lot Number(s)30842-S-75076196
Washer Mfg. Lot Number(s)D7353 Bolt SpecificationASTM A325
Bolt Length(s)2-1/4" Nut SpecificationASTM A 563-DH
Washer SpecificationF436 FinishHDG
Diameter/Size7/8" Bolt Mfg. Lot NumberBG1493
Rocap Test Requirement(s) Lubricant Requirements(s)Lubricated

Test Details

DIME Sample ID: 2020-07-31-3
DIME Test ID: 2020-07-31-3-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2020-08-12

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 08/06/2020
UTM: 450kip
Temperature: 72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11B30842-7507619672628Nut Profffsaylor

General comments (publicly viewable) (Max 1000 characters): Nut Proff
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 8/12/2020