Summary for Test 2020-08-03-4-1

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 212501
DEA: 022E4804
EFIS: 0200000586
DIST-CO-RTE-PM02-SIS-96,263-103.1/103.6,56.8/57.2
Award Date12/14/2018
Closeout Date12/01/2021
Work DescriptionBRIDGE REPLACEMENT
Location DescriptionSISKIYOU COUNTY ABOUT 8 MILES NORTH OF YREKA ON ROUTE 96 FROM 0.5 MILE WEST TO 0.2 MILE EAST OF ROUTE 263 AND ON ROUTE 263 FROM 0.3 MILE NORTH OF SHASTA RIVER BRIDGE #02-0014 TO ROUTE 96
QA Service Level1 (Verified on 06/06/2017)

Sample Information

Sample Taken Date08/03/2020 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/06/2020
Sample typeQuality Assurance A brief description of the sample1/2" x 3-1/2" A325 bolts, 1/2" A563-DH nuts and 1/2" F436 washers
The quantity of what the sample constitutes87/87/174 From where was the sample collectedFabricator
First name of sampler or witnessed byCraig Last name of sampler or witnessed byHager
Title of samplerQA Inspector Telephone number of sampler925-899-1184
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameUIS Lindon UT Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB29-033-20 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)TT0131087
Heat Number(s)bolts - 20495460, nuts - 20650010, washers - 190394 Nut Mfg. Lot Number(s)L511Q1
Washer Mfg. Lot Number(s)957-190394 Bolt SpecificationA325
Bolt Length(s)3-1/2 in. Nut SpecificationA563-DH
Washer SpecificationF436 FinishHDG - all
Diameter/Size1/2 in. Bolt Mfg. Lot NumberG9825
Rocap Test Requirement(s)Yes Lubricant Requirements(s)none

Test Details

DIME Sample ID: 2020-08-03-4
DIME Test ID: 2020-08-03-4-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2020-08-12

Test Results


Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 08/06/2020
UTM: 450kip
Temperature: no data
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
11G98250.50002023590.0110.00A325 Boltfsaylor

General comments (publicly viewable) (Max 1000 characters): A325 Bolt
Test Graph
Source: Bluehill Data Point File

Test was verified on 8/12/2020