Summary for Test 2020-08-03-4-1
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 212501 DEA: 022E4804 EFIS: 0200000586 |
---|---|
DIST-CO-RTE-PM | 02-SIS-96,263-103.1/103.6,56.8/57.2 |
Award Date | 12/14/2018 |
Closeout Date | 12/01/2021 |
Work Description | BRIDGE REPLACEMENT |
Location Description | SISKIYOU COUNTY ABOUT 8 MILES NORTH OF YREKA ON ROUTE 96 FROM 0.5 MILE WEST TO 0.2 MILE EAST OF ROUTE 263 AND ON ROUTE 263 FROM 0.3 MILE NORTH OF SHASTA RIVER BRIDGE #02-0014 TO ROUTE 96 |
QA Service Level | 1 (Verified on 06/06/2017) |
Sample Information
Sample Taken Date | 08/03/2020 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/06/2020 |
Sample type | Quality Assurance | A brief description of the sample | 1/2" x 3-1/2" A325 bolts, 1/2" A563-DH nuts and 1/2" F436 washers |
The quantity of what the sample constitutes | 87/87/174 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Craig | Last name of sampler or witnessed by | Hager |
Title of sampler | QA Inspector | Telephone number of sampler | 925-899-1184 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | UIS Lindon UT | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B29-033-20 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | TT0131087 |
---|---|---|---|
Heat Number(s) | bolts - 20495460, nuts - 20650010, washers - 190394 | Nut Mfg. Lot Number(s) | L511Q1 |
Washer Mfg. Lot Number(s) | 957-190394 | Bolt Specification | A325 |
Bolt Length(s) | 3-1/2 in. | Nut Specification | A563-DH |
Washer Specification | F436 | Finish | HDG - all |
Diameter/Size | 1/2 in. | Bolt Mfg. Lot Number | G9825 |
Rocap Test Requirement(s) | Yes | Lubricant Requirements(s) | none |
Test Details
DIME Sample ID: 2020-08-03-4
DIME Test ID: 2020-08-03-4-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2020-08-12
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 08/06/2020
UTM: 450kip
Temperature: no data
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 1 | G9825 | 0.5000 | 20235 | 90.01 | 10.00 | A325 Bolt | fsaylor |
General comments (publicly viewable) (Max 1000 characters): A325 Bolt
Test Graph
Source: Bluehill Data Point FileTest was verified on 8/12/2020 ✔