Test 2020-07-25-8-2 (CTM 670-December 2013) Summary

Project Information
Project IdentifiersProject ID: 213958
DEA: 010F9604
EFIS: 0116000109
DIST-CO-RTE-PM01-HUM-101-124.5
Work DescriptionLITTLE LOST MAN FISH PASSAGE
Location DescriptionHUMBOLDT COUNTY NEAR ORICK 0.2 MILE SOUTH OF LOST MAN CREEK BRIDGE
Sample Information
Sample Taken Date7/25/2020 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing8/4/2020
Sample typeQuality Assurance A brief description of the sampleGriptwist Couplers
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byJoshua Last name of sampler or witnessed byLee
Title of sampler Laboratory sample identification
The fabricator/manufacturer/facility nameCascade Barsplice Transportation Laboratory (TL) NumberC972551
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCascade Steel
Coupler ManufacturerBarSplice Intermediate Assembler or Fabricator
Rebar Size#8 Coupler ModelGrip Twist
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)A194656 Rebar Heat Number(s)3092107
Rebar Size 2
Test Details
DIME Sample ID: 2020-07-25-8
DIME Test ID: 2020-07-25-8-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2020-08-04
Test Results

Number of Samples Tested: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 08/04/2020
UTM:400kip
Temperature:72.00 f
Halo ID:
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
12No. 8/25mm100.797548195546Service Splicefsaylor

General comments (publicly viewable) (Max 250 characters): Service Splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 08/04/2020