Test 2020-07-30-3-1 (ASTM A970-15e1) Summary

Project Information
Project IdentifiersProject ID: 211848
DEA: 112T2174
EFIS: 1116000131
DIST-CO-RTE-PM11-SD-5-R37.4 - R46.5
Work Description(Alternative Delivery) CMGC, San Elijo Highway Bridge Replacement. Replace the San Elijo lagoon highway bridge, construct HOV lanes, construct bike and pedestrian trails and bridge, build multi-use facility at Manchester Ave.
Location DescriptionIN SAN DIEGO COUNTY IN SOLANA BEACH AND ENCINITAS FROM 0.1 MILE NORTH OF LOMAS SANTA FE DRIVE OVERCROSSING TO 0.2 MILE SOUTH OF BIRMINGHAM DRIVE OVERCROSSING
Sample Information
Sample Taken Date7/30/2020 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing8/3/2020
Sample typeQuality Assurance A brief description of the sample555 T-Headed Reinforcing #11 bar
The quantity of what the sample constitutes4 From where was the sample collectedSource
First name of sampler or witnessed byNick Last name of sampler or witnessed byHoffmann
Title of samplerQA Inspector Laboratory sample identification
The fabricator/manufacturer/facility nameCMC Rebar Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)3093850, 3096957, 3092498 Head Manufacturer Lot Number(s)Lot 9
Rebar Size#11 Headed Bar Model NameHRC 555
Size of HeadReduced Size - 4x Head Connection TypeForged
Head ShapeCircular Rebar ManufacturerCMC Rebar
Head ManufacturerHRC CMC Head FabricatorHRC
Material Standard CodeASTM A706
Test Details
DIME Sample ID: 2020-07-30-3
DIME Test ID: 2020-07-30-3-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2020-08-03
Test Results

Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 08/03/2020
UTM: 400kip
Temperature:72 f
NumLot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
181.5614491292892OK Neckingfsaylor

General comments (publicly viewable) (Max 250 characters): OK Necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 08/03/2020