Summary for Test 2015-01-09-2-1
Test performed: CTM 643-June 2007Project Information
Project Identifiers | Project ID: 3959 DEA: 072159C4 EFIS: 0700000339 |
---|---|
DIST-CO-RTE-PM | 07-LA-5-001.8/003.0 |
Award Date | 08/19/2011 |
Closeout Date | 08/16/2018 |
Work Description | CARMENITA INTERCHANGE IMPROVEMENT |
Location Description | LOS ANGELES COUNTY IN SANTA FE SPRINGS AND NORWALK FROM ALONDRA BOULEVARD OVERCROSSING TO SHOEMAKER AVENUE OVERCROSSING |
QA Service Level | 1 (Verified on 05/01/2012) |
Sample Information
Sample Taken Date | 01/09/2015 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/09/2015 |
Sample type | Acceptance | A brief description of the sample | Structural Backfill Material |
The quantity of what the sample constitutes | 2 Bags | From where was the sample collected | Source |
First name of sampler or witnessed by | Calvin | Last name of sampler or witnessed by | Dao |
Title of sampler | TEC | Telephone number of sampler | Unknown |
Laboratory sample identification | 5009B | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | At RW 13 | Transportation Laboratory (TL) Number | C903701 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
Structure name | Not set |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Unknown |
---|---|---|---|
The fabricator/manufacturer designation for the sample | Unknown | A detailed description of where the material sample was collected | At RW 13 |
Where the material sample would have been placed if not sampled | Unknown |
Test Details
DIME Sample ID: 2015-01-09-2
DIME Test ID: 2015-01-09-2-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 643-June 2007: Method for Determining Field and Laboratory Resistivity and pH Measurements for Soil and Water
Test Release Date: 2015-02-23
Test Results
The test method used?: Laboratory Resistivity Test for Soil
Input Type: Calculated
Tester's full name: Vincent Onoh
Date of test: 01/14/2015
Soil sample resistance (lab measure 1): 14000 Ohms
Soil sample resistance (lab measure 2): 9650 Ohms
Soil sample resistance (lab measure 3): 9100 Ohms
Soil sample resistance (lab measure 4): 9200 Ohms
Soil sample resistance (lab measure 5): no data Ohms
Soil sample resistance (lab measure 6): no data Ohms
Soil sample resistance (lab measure 7): no data Ohms
Soil sample resistance (lab measure 8): no data Ohms
Soil sample resistance (lab measure 9): no data Ohms
Soil sample resistance (lab measure 10): no data Ohms
Soil sample resistance (lab measure 11): no data Ohms
Soil sample resistance (lab measure 12): no data Ohms
Minimum soil resistance of the lab measurement: 9100 Ohms
Soil sample temperature: 19.3 C
Soil box constant: 1
pH of soil: 8.69
Minimum soil resistance corrected to 15.5: 9965 Ohms
Minimum soil resistivity at 15.5: 9965 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/23/2015 ✔