Summary for Test 2020-06-30-43-7

Test performed: AASHTO T335-09r13

Project Information

Project IdentifiersProject ID: 214059
DEA: 042K7504
EFIS: 0417000019
DIST-CO-RTE-PM04-SCL-152-7.6/M10.2
Award Date05/24/2019
Closeout Date04/12/2021
Work DescriptionROADWAY REHAB, CURB RAMPS, SIGNALS, AND STRIPING UPGRADES.
Location DescriptionSANTA CLARA COUNTY IN GILROY FROM 0.3 MILE WEST OF SANTA TERESA BOULEVARD TO ROUTE 101
QA Service Level1 (Verified on 06/04/2019)

Sample Information

Sample Taken Date06/30/2020 Sample Unique Key43
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing08/02/2020
Sample typeVerification A brief description of the sample3/8" HMA Aggregate
The quantity of what the sample constitutesJMF 16 Bags From where was the sample collectedManufacturer
First name of sampler or witnessed byPurvi Last name of sampler or witnessed byShah
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite Construction Company Transportation Laboratory (TL) Number810423
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-24-0009
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedHot Plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/8 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-06-30-43
DIME Test ID: 2020-06-30-43-7
Testing Lab: CT D04 - Hayward DME / District Laboratory
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Test Release Date: 2020-07-31

Test Results


Method: 1 - Combined Fracture Determination
Aggregate Size and Fracture Type: Coarse 1 and 2 Faced and Fine 1 Faced
Input Type: Calculated
Tester's full name: Babak Kamranimoghaddam
Date of test: 07/08/2020
Percentage of fractured, coarse, 2 faced particles tested: 97 %
Percentage of fractured, coarse, 1 faced particles tested: 100 %
Percentage of fractured, fine, 1 faced particles tested: 100 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/31/2020