Summary for Test 2020-07-28-1-2

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 212535
DEA: 031A9204
EFIS: 0300020608
DIST-CO-RTE-PM03-SUT-20-5-11.3
Award Date06/11/2019
Closeout Date12/01/2021
Work DescriptionSUTTER BYPASS WIDENING AND REHAB
Location DescriptionNEAR YUBA CITY FROM SUTTER BYPASS TO 0.1 MILE WEST OF LYTLE ROAD.
QA Service Level1 (Verified on 07/23/2018)

Sample Information

Sample Taken Date07/28/2020 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/28/2020
Sample typeQuality Assurance A brief description of the sampleGriptwist Couplers
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byMorgan Last name of sampler or witnessed byWilson
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCMC BarSplice Transportation Laboratory (TL) NumberC
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC Rebar
Coupler ManufacturerBarSplice Intermediate Assembler or Fabricator
Rebar Size#10 Coupler ModelBarsplice Griptwist coupler
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)A201362 Rebar Heat Number(s)4092806
Rebar Size 2 Coupler Unique IDNot set

Test Details

DIME Sample ID: 2020-07-28-1
DIME Test ID: 2020-07-28-1-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2020-07-28

Test Results


Number of Samples Tested: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 07/28/2020
UTM: 2000kip
Temperature: 72.00 f
Halo ID: Large
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
11No. 10/32mm1-0.00171.2712490298348OK Neckingfsaylor

General comments (publicly viewable) (Max 1000 characters): OK Necking
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 7/28/2020