Test 2020-07-10-6-1 (AASHTO T27-14) Summary

Project Information
Project IdentifiersProject ID: 212112
DEA: 080C2514
EFIS: 0816000076
COOP: 081645
DIST-CO-RTE-PM08-SBD-10-0.0/13.2
Work DescriptionDesign-Build of I-10 Corridor Contract 1 - Adding 2 new Express Lanes
Location DescriptionLA/SBD County Line to PM 13.2 near I-15
Sample Information
Sample Taken Date7/10/2020 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing7/14/2020
Sample typeVerification A brief description of the sampleJMF 1/2" HMA-A-SP R15 0.50% LAS Aggregate aand RAP
The quantity of what the sample constitutes4 Bags Coldfeed Aggregate, 2 Bags Rap From where was the sample collectedManufacturer
First name of sampler or witnessed byVulcan Irwindale Last name of sampler or witnessed byQC
Title of sampler Laboratory sample identification0431A-20
The fabricator/manufacturer/facility nameVulcan Materials-Irwindale Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-19-0035
The fabricator's/manufacturer's product name for the sample1/2 HMA-A-SP R15 The fabricator/manufacturer designation for the sample
The plant number324108A IRW SJR A detailed description of where the material sample was collectedBelt Cut at Vulcan Irwindale Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number JMF Verification ID
Test Details
DIME Sample ID: 2020-07-10-6
DIME Test ID: 2020-07-10-6-1
Testing Lab: CT - Southern Regional Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2020-07-27
Test Results

What type of gradation is being tested?: Combined Gradation
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Input Type: Calculated
Tester's full name: Edmond Jabbour, Satish Jain
Date of test: 07/16/2020
Cumulative percent passing the 2 in. sieve:100 %
Cumulative percent passing the 1 1/2 in. sieve:100 %
Cumulative percent passing the 1 in. sieve:100 %
Cumulative percent passing the 3/4 in. sieve:100 %
Cumulative percent passing the 1/2 in. sieve:96 %
Cumulative percent passing the 3/8 in. sieve:84 %
Cumulative percent passing the #4 sieve:56 %
Cumulative percent passing the #8 sieve:37 %
Cumulative percent passing the #16 sieve:24 %
Cumulative percent passing the #30 sieve:16 %
Cumulative percent passing the #50 sieve:11 %
Cumulative percent passing the #100 sieve:7 %
Cumulative percent passing the #200 sieve:4.8 %
General comments (publicly viewable) (Max 1000 characters): Combined Virgin Aggregate Gradation

Test was verified on 07/27/2020