Summary for Test 2020-07-16-6-11
Test performed: ASTM D4791-10Project Information
Project Identifiers | Project ID: 213741 DEA: 07325704 EFIS: 0716000089 |
---|---|
DIST-CO-RTE-PM | 07-LA-5-1.7 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | BUILDING CONSTRUCTION IN LOS ANGELES COUNTY IN SANTA FE SPRINGS AT 14044 FREEWAY DRIVE. |
Location Description | Santa Fe Springs, At 14044 Freeway Drive. |
QA Service Level | 1 (Verified on 07/08/2019) |
Sample Information
Sample Taken Date | 07/16/2020 | Sample Unique Key | 6 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/17/2020 |
Sample type | Verification | A brief description of the sample | PSUE 1/2" WMA-A-SP R25 0.25% Evo Aggregate and RAP |
The quantity of what the sample constitutes | 2 Bags Combined Agg., 1 Bag Rap | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Robert | Last name of sampler or witnessed by | Trao |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 0441A-20 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | RJ Noble Orange | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-33-0014/ 91-33-0035 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | 1/2 WMA-A-SP R25 | The fabricator/manufacturer designation for the sample | |
The plant number | 40R2507SPWEO | A detailed description of where the material sample was collected | Belt Cut at RJ Noble Orange Plant |
Where the material sample would have been placed if not sampled | Asphalt Paving | Primary Aggregate Nominal Size | 1/2 inch |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2020-07-16-6
DIME Test ID: 2020-07-16-6-11
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Test Release Date: 2020-07-23
Test Results
Method A - Percentage of Flat Particles, Elongated Particles, and Flat & Elongated Particles
Method B - Flat & Elongated Particles
Method: B
Determination: By Mass
Dimensional ratio used: 5:1
Input Type: Calculated
Tester's full name: Satish Jain
Date of test: 07/22/2020
Weighted percentage of particles (by mass) that were flat and elongated: 4 %
Weighted percentage of particles (by mass) that were not flat and elongated: 96 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/23/2020 ✔