Summary for Test 2020-07-16-6-6

Test performed: AASHTO T176-08

Project Information

Project IdentifiersProject ID: 213741
DEA: 07325704
EFIS: 0716000089
DIST-CO-RTE-PM07-LA-5-1.7
Award DateNot set
Closeout DateNot set
Work DescriptionBUILDING CONSTRUCTION IN LOS ANGELES COUNTY IN SANTA FE SPRINGS AT 14044 FREEWAY DRIVE.
Location DescriptionSanta Fe Springs, At 14044 Freeway Drive.
QA Service Level1 (Verified on 07/08/2019)

Sample Information

Sample Taken Date07/16/2020 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/17/2020
Sample typeVerification A brief description of the samplePSUE 1/2" WMA-A-SP R25 0.25% Evo Aggregate and RAP
The quantity of what the sample constitutes2 Bags Combined Agg., 1 Bag Rap From where was the sample collectedManufacturer
First name of sampler or witnessed byRobert Last name of sampler or witnessed byTrao
Title of sampler Telephone number of sampler
Laboratory sample identification0441A-20 Linked DIME Sample ID
The fabricator/manufacturer/facility nameRJ Noble Orange Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0014/ 91-33-0035
The fabricator's/manufacturer's product name for the sample1/2 WMA-A-SP R25 The fabricator/manufacturer designation for the sample
The plant number40R2507SPWEO A detailed description of where the material sample was collectedBelt Cut at RJ Noble Orange Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-07-16-6
DIME Test ID: 2020-07-16-6-6
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2020-07-23

Test Results


How many times will the test be run?: 3 Times
Input Type: Measured
Tester's full name: Larry Diaz
Date of test: 07/19/2020
Clay Level (Test 1): 5.3
Sand Level (Test 1): 3.6
Clay Level (Test 2): 5.3
Sand Level (Test 2): 3.7
Clay Level (Test 3): 5.4
Sand Level (Test 3): 3.7
Sand Equivalent (Test 1): 68
Sand Equivalent (Test 2): 70
Sand Equivalent (Test 3): 69
Sand Equivalent: 69
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/23/2020