Summary for Test 2020-07-09-27-2

Test performed: ASTM D5329-16

Project Information

Project IdentifiersProject ID: 214689
DEA: 051M0204
DIST-CO-RTE-PM05-SBT-129-0.3/R2.6
Award Date04/02/2020
Closeout Date10/29/2020
Work DescriptionCOLD PLANE AND OVERLAY EXISTING ROADWAY WITH RHMA-G.
Location DescriptionSAN BENITO COUNTY ABOUT 10 MILES EAST OF WATSONVILLE FROM 0.1 MILE WEST OF SCHOOL ROAD TO 0.1 MILE EAST OF ROUTE 101/129 SEPARATION
QA Service Level1 (Verified on 02/20/2020)

Sample Information

Sample Taken Date07/09/2020 Sample Unique Key27
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/13/2020
Sample typeAcceptance A brief description of the sampleRubber Asphalt Binder
The quantity of what the sample constitutes1 can, TEST #1 (972752) From where was the sample collectedSource
First name of sampler or witnessed byI Last name of sampler or witnessed byVasquez
Title of samplerQC RTS Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameSan Joaquin Refinery Transportation Laboratory (TL) Number972752
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Rubber Binder Asphalt modifier supplier
Performance GradePG 64-16 Lot number1
Sublot number1 Asphalt Rubber Binder Mix NumberNot set

Test Details

DIME Sample ID: 2020-07-09-27
DIME Test ID: 2020-07-09-27-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Test Release Date: 2020-07-22

Test Results


Input Type: Measured
Tester's full name: Juan Gomez
Date of test: 07/21/2020
Temperature: no data
Final Dial reading (F1): no data
Ball Penetration (P1): no data
Final Dial reading (F2): no data
Ball Penetration (P2): no data
Final Dial reading (F3): no data
Ball Penetration (P3): no data
Resilience 1: no data
Resilience 2: no data
Resilience 3: no data
Average Resilience: 22 %
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/22/2020