Summary for Test 2020-07-17-2-4
Test performed: AASHTO T283-14Project Information
Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 07/17/2020 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/20/2020 |
Sample type | Aggregate Prequalification Program | A brief description of the sample | JMF Prequalification Program |
The quantity of what the sample constitutes | 16 boxes | From where was the sample collected | Source |
First name of sampler or witnessed by | Christopher | Last name of sampler or witnessed by | Escobar |
Title of sampler | QC Operations Supervisor | Telephone number of sampler | 209-234-3571 |
Laboratory sample identification | 482 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Granite Construction Company Vernalis | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | |
Sublot number | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2020-07-17-2
DIME Test ID: 2020-07-17-2-4
Testing Lab: Granite Construction Company - Tracy
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Test Release Date: 2020-07-17
Test Results
Unit system used?: SI Units
Input Type: Calculated
Tester's full name: Chris Escobar
Date of test: 05/20/2020
Specimen Treatment: Treated
Average Dry Tensile Strength: 276 psi
Average Wet Tensile Strength: 155 psi
Tensile Strength Ratio: 56
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/17/2020 ✔