Summary for Test 2014-12-08-1-3

Test performed: CTM 643-June 2007

Project Information

Project IdentifiersProject ID: 7613
DEA: 071218W4
EFIS: 0700021119
DIST-CO-RTE-PM07-LA-5-29.4/31.6
Award Date11/29/2012
Closeout Date07/31/2023
Work DescriptionREALIGN ROUTE 5 AND RAILROAD TRACKS AND RECONFIGURE ON- AND OFF-RAMPS.
Location DescriptionLOS ANGELES COUNTY IN BURBANK FROM WEST MAGNOLIA BOULEVARD OVERCROSSING TO 0.3 MILE NORTH OF BUENA VISTA STREET/WINONA AVENUE UNDERCROSSING
QA Service Level1 (Verified on 10/08/2012)

Sample Information

Sample Taken Date12/08/2014 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/15/2014
Sample typeAcceptance A brief description of the sampleBackfill Material
The quantity of what the sample constitutes2 Bags From where was the sample collectedOther
First name of sampler or witnessed byUnknown Last name of sampler or witnessed byUnknown
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identification4332B Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameMSE Storage Pile Santa Clarita Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sampleUnknown
The fabricator/manufacturer designation for the sampleUnknown A detailed description of where the material sample was collectedMSE Storage Pile Santa Clarita
Where the material sample would have been placed if not sampledUnknown

Test Details

DIME Sample ID: 2014-12-08-1
DIME Test ID: 2014-12-08-1-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 643-June 2007: Method for Determining Field and Laboratory Resistivity and pH Measurements for Soil and Water
Test Release Date: 2015-02-23

Test Results


The test method used?: Laboratory Resistivity Test for Soil
Input Type: Calculated
Tester's full name: Vincent Onoh
Date of test: 12/17/2014
Soil sample resistance (lab measure 1): 5800 Ohms
Soil sample resistance (lab measure 2): 5200 Ohms
Soil sample resistance (lab measure 3): 5400 Ohms
Soil sample resistance (lab measure 4): no data Ohms
Soil sample resistance (lab measure 5): no data Ohms
Soil sample resistance (lab measure 6): no data Ohms
Soil sample resistance (lab measure 7): no data Ohms
Soil sample resistance (lab measure 8): no data Ohms
Soil sample resistance (lab measure 9): no data Ohms
Soil sample resistance (lab measure 10): no data Ohms
Soil sample resistance (lab measure 11): no data Ohms
Soil sample resistance (lab measure 12): no data Ohms
Minimum soil resistance of the lab measurement: 5200 Ohms
Soil sample temperature: 20.7 C
Soil box constant: 1
pH of soil: 8.99
Minimum soil resistance corrected to 15.5: 5876 Ohms
Minimum soil resistivity at 15.5: 5876 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/23/2015